Manufacturer of Petroleum Test Equipment since 1873

Product   

 Flash-Point with Closed/Open Cup - Rapid Tester "Series 3"
(automatic flash detection)


Main Unit   

12-1240

 

Rapid Flash-Point Tester "Series 3" (closed cup)

Flash-Point Method:
IP 523 (IP 303-1) - ASTM D 3828-B - ISO 3679
(BS 6664-4, EN 456, NF T60-616) - JIS K2265
ASTM D 3278-B - UN Class 3 N - ASTM E 502

Flash / no Flash Method:
IP 524 (IP 303-2) - ASTM D 3828-A - ISO 3680
(BS 6664-3, DIN 55 680, NF T60-617)
ASTM D 3278-A

Consisting of:
housing with touch-key panel and LC-display, integrated aluminum cup, cover with shutter assembly, built-in gas igniter at the cover, timer, digital temperature pre-selection in °Celsius/Fahrenheit, automatic flash-point detection

Supplied with:
1 syringe 2 ml
1 rechargeable gas tank with igniter

Power supply: 115/220 V, 50/60 Hz (switchable)

 


12-1260

 

Rapid Flash-Point Tester "Series 3"
(non-corrosive cup + active cool)

Flash-Point Method:
IP 523 (IP 303-1) - ASTM D 3828-B - ISO 3679
(BS 6664-4, EN 456, NF T60-616) - JIS K2265
ASTM D 3278-B - UN Class 3 N - ASTM E 502

Flash / no Flash Method:
IP 524 (IP 303-2) - ASTM D 3828-A - ISO 3680
(BS 6664-3, DIN 55 680, NF T60-617)
ASTM D 3278-A

Ramp Method: ASTM D 7236

Consisting of:
Like 12-1240, but fitted with special stainless steel cup, suitable for testing corrosive samples and electronic Peltier cooling with rapid cool down.

Temperature Range: +10 to +110 °C

Power supply: 115/220 V, 50/60 Hz (switchable)

 


12-1241

 

Rapid Flash-Point Tester "Series 3" (open cup)

Fire-Point Method:
ASTM D 4206 - ISO 9038 (NF T30-068) - BS 3900-A11
UN Class 3 L.3 - CFR 49-173.120

Consisting of:
like 12-1240, but with an open cup for flash / no flash, finite determinations or sustained combustion tests.

A manually operated flame-sweeping arm is fitted to the cup and gas is supplied from the integral tank via the control valve. The flash or sustained combustion characteristics of the sample are observed visually by passing the test flame over the sample.

Power supply: 115/220 V, 50/60 Hz (switchable)

 
Options & Accessories   

12-0076

 

Coolant Module (for 12-1208 / -1240 / -1241)

for pre-cool the cooling block when measuring sub-ambient
(charged with dry ice)

 

12-0086

 

Cooling Block

aluminum, to cool-down the sample cup after testing without cooling-water

 

12-1243

 

Adapter for power supply

allows instrument to be operated from 12 V supply

 

12-1244

 

Carry Case

Consisting of:
foam cutouts to house instrument, gas tank, power supply and syringe
Dimensions (HxWxD): 21 x 40 x 30 cm

 

12-1248

 

Sample Removal Kit

with pump and trap to extract and collect used sample from cup after test.

 

12-1252

 

Reference Liquid (Kerosene) certified

50 ml, nominal value +66 °C

 
Spare Parts   

12-1245

 

Thermometer

Range: 0 to +110 °C (officially certified)

 

12-1247

 

Thermometer

Range: +100 to +300 °C (officially certified)

 

12-0081

 

Syringe, 2 ml

 

12-1246

 

Syringe, 4 ml

for high temperature tests above +100 °C, which needs a larger size

 

12-1250

 

Gas Tank (portable and refillable)

Gas Tank (portable and refillable)

Consisting of:
built-in on/off switch, igniter and stand

Supplied with: 1 m gas tubing

Note:
To be filled by using any standard gas lighter refill cartridge. We highly recommend to buy the LPG - refill container locally, because it would require special shipment as hazardous goods.

 
Order Guideline   

Minimum equipment:

1x 12-1240 or 1x 12-1260 or 1x 12-1241

Spares (approx. 1 year):

Thermometer, 12-1246, 12-1252

Additional requirements:

Liquefied Petroleum Gas Supply