| Product |
Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)
| Main Unit |
12-0501 | ABA 4 - Automatic Flash-Point Tester |
|
Abel Method (air cooled) Abel Method: Abel Bitumen Method: Equilibrium Method: with further accessories for: Abel-Pensky Method: Consisting of: PC-Software "FPPnet" (Windows®): Supplied with: Temperature Range: +10 to +110 °C (+50 to +230 °F) Power supply: 115/230 V, 50/60 Hz, 180 W, EU-plug |
||
12-0502 | ABA 4 - Automatic Flash-Point Tester, |
|
Abel Method (air cooled) Like 12-0501 but: |
||
12-0503 | ABA 4 - Automatic Flash-Point Tester, |
|
Abel Method (liquid cooled) Abel Method: Equilibrium Method: with further accessories for: Abel-Pensky Method: Consisting of: Software (Windows®): see 12-0501 (air cooled) Supplied with: see 12-0501 (air cooled) Note: Circulation cooler (e.g. 25-0382) is required. Temperature Range: -30 to +110 °C (-22 to +230 °F) Power supply : 230 V, 50/60 Hz, EU-plug |
||
12-0504 | ABA 4 - Automatic Flash-Point Tester, |
|
Abel Method (liquid cooled) Like 12-0503 but: |
||
| Options & Accessories |
25-0382 | Circulation Cooler (-20/+40) with insulated hose set |
|
![]() | For cooling of instruments without circulation pump (external tempering). Consisting of: Supplied with: 1 insulated hose-set (Ø 8 mm, 2x 2m) Technical Data: |
|
25-0228 | Hose-Set (Ø 8 mm) |
|
insulated, 2 x 2 m, incl. fittings |
||
12-0518 | Insulating Hood - ABA/TAG |
|
![]() | to protect the cover and shutter assembly from icing. |
|
12-0520 | Calibration Set - ABA |
|
Consisting of:
|
||
50-9023 | Reference Liquid - MTVM - Type: Kerosene |
|
Distillation: ASTM D 86, IP 123, ISO 3405
|
||
12-1760 | Holding Device for Multi-Detector (PMA & ABA/TAG) |
|
![]() | suitable for:
|
|
12-1508 | Draft Deflector (recommended for gas ignition tests) |
|
12-1509 | Stand to hold 12 multi-detectors |
|
12-1763 | Storage Box |
|
![]() | for spare parts and tools |
|
25-0282 | Impact Printer (mono) |
|
![]() | for single sheets & continuous paper
Supplied with: 2 data cables (9-pin 25-0304, USB 25-0918), 1 ink ribbon (black) Technical Data: |
|
11-0599 | USB/RS232-Converter (verified for petrotest®-units) |
|
![]() | with 2 m cable connecting 1 serial port with the USB-port of a PC or Hub |
|
12-1514 | Rapidflash Simulation Set |
|
![]() | Consisting of: Note! Flash-point results of rapidflash simulation may deviate from standard results. |
|
12-1515 | Rapidflash Cup |
|
12-1516 | Rapidflash Cover, with shuttler assembly |
|
12-1518 | Syringe for sample introduction, 10 ml |
|
12-0577 | Multi-Detector - pAB/pTA |
|
![]() | for milli-tests or rapidflash-tests, |
|
12-0574 | Milli Cover - pAB, with shutter assembly |
|
Note! Flash-point results of milli test inserts may deviate from standard results. |
||
12-0575 | Milli Cup - pAB |
|
for sample quantity between 2 ... 15 ml, ideal 7 ml |
||
12-0577 | Multi-Detector - pAB/pTA |
|
![]() | for milli-tests or rapidflash-tests, |
|
12-1512 | Cover - ABEL-PENSKY, for older AP standards |
|
![]() | with shutter assembly (without a stirrer)
|
|
12-0510 | Standard Test Insert - ABA (incl. in ABA 4) |
|
Consisting of: |
||
12-2513 | Standard Multi-Detector - ABA, with DKD-certificate |
|
![]() | Like 12-0513 but: |
|
| Spare Parts |
12-0511 | Standard Cup - ABA, 79 ml |
|
12-0512 | Standard Cover - ABA, with shutter assembly |
|
12-0513 | Standard Multi-Detector - ABA |
|
![]() | with flash-point detector (thermocouple) and temperature probe |
|
12-0778 | Electric Igniter |
|
![]() | with connector cable and plugs |
|
12-0509 | Gas Igniter with 25 cm hose |
|
12-0514 | Safety Detector |
|
to control gas igniter and external inflammation |
||
12-0600 | Tray for cup and multi-detector |
|
Note! Available as an option for all units built before 05/2004. |
||
12-5790 | Tong for test cups without handle |
|
safe handling of hot test inserts |
||
12-1507 | Stirrer Couplings , pack of 10 |
|
12-0791 | Stopper, brass (Ø 18 mm) |
|
to close the thermometer or multi-detector opening of the cover before use |
||
| Order Guideline |
Minimum equipment: |
1x 12-0501 or 1x 12-0503, 1x 25-0382, 1x 25-0228 |
Spares (approx. 1 year): |
1 each: 12-0778, 12-0513, 12-1507 |
Additional requirements: |
gas supply, PC recommended |