Manufacturer of Petroleum Test Equipment since 1873

Product   

 Flash-Point with Closed Cup - TAG Method - TAG 4 (automatic)


Main Unit   

12-0540

 

TAG 4 - Automatic Flash-Point Tester

TAG Method (air cooled)

TAG Method: ASTM D 56 - FTM 791-1101 - JIS K2265-1

Equilibrium Method:
ASTM D 3941 - ISO 1523 - IP 492 (IP 304-1) - EN 924

Equilibrium Method (flash/ no flash):
ASTM D 3934 - ISO 1516 - IP 491 (IP 304-2)

with further accessories for:
Rapid Equilibrium-Simulation:
ISO 3679 (BS 6664-4, EN 456, NF T60-616 ) -
ISO 3680 (BS 6664-3, DIN 55 680, NF T60-617)

Consisting of:
high-grade stainless steel housing with two-color powder coating, touch-key panel with large LC-display (visible in up to 10 m distance), swivel-mounted Multi-Function-Head - ONE-TWIST, two RS232-interfaces for data printer and computer connection, different test-programs, data-transfer and software upgrading through bi-directional interface, Peltier element system, automatic barometric pressure control (correction), automatic overheat protection, power controlled/monitored electric igniter, gas igniter with auto-relighting and safety shut-off, re-cooling fan

PC-Software "FPPnet" (Windows®):
A control & analysis program for easy handling, data storage and program transfer. Providing online display of sample & heater block temperature, gradient (also in an XY-diagram) and test status. Easy to read tableau indicating: sample no., sample name, °C/°F, expected flash point, program, status, found flash point, corrected flash point, corrected rounded flash point. Test results are stored together with all program and device parameters in one file. The simultaneous connection of different petrotest® flash point devices is possible. To simplify the device management they can be named individually.

Supplied with:
1 cup "TAG"
1 cover "TAG"
1 multi-detector "TAG"
1 gas igniter
1 electric igniter
1 stopper
1 tong for cup
1 tray for cup and multi-detector
1 PC-software "FPPnet"

Temperature Range: 0 to +110 °C (+32 to +230 °F)

Power supply : 115/230 V, 50/60 Hz, EU-Plug

 

12-0541

 

TAG 4 - Automatic Flash-Point Tester

TAG Method (air cooled)

Like 12-0540 but:
Power supply : 115/230 V, 50/60 Hz, US-Plug

 

12-0542

 

TAG 4 - Automatic Flash-Point Tester

TAG Method (liquid cooled)

TAG Method: ASTM D56 - FTM 791-1101 - JIS K 2265

Equilibrium Method:
ASTM D 3941 - ISO 1523 - IP 492 (IP 304-1) - EN 924

Equilibrium Method (flash/ no flash):
ASTM D 3934 - ISO 1516 - IP 491 (IP 304-2)

with further accessories for:
Rapid Equilibrium-Simulation:
ISO 3679 (BS 6664-4, EN 456, NF T60-616 ) -
ISO 3680 (BS 6664-3, DIN 55 680, NF T60-617)

Consisting of:
see 12-0540, but with cooler connection for external liquid cooling.

Software (Windows®): see 12-0540

Supplied with: see 12-0540

Note: Circulation cooler (e.g. 25-0382) is required.

Temperature Range: -30 to +110 °C (-22 to +230 °F)

Power supply: 230 V, 50/60 Hz, EU-plug

 

12-0543

 

TAG 4 - Automatic Flash-Point Tester

TAG Method (liquid cooled)

Like 12-0542 but:
Power supply: 115 V, 60 Hz, US-plug

 
Options & Accessories   

12-1508

 

Draft Deflector (recommended for gas ignition tests)

 

12-0518

 

Insulating Hood - ABA/TAG

Insulating Hood as ice protection

to protect the cover and shutter assembly from icing.
Recommended for low temperature flash-point tests,
made of Styrofoam®.

 

25-0228

 

Hose-Set (Ø 8 mm)

insulated, 2 x 2 m, incl. fittings

 

25-0382

 

Circulation Cooler (-20/+40) with insulated hose set

Circulation Cooler

For cooling of instruments without circulation pump (external tempering).
Economical solution for cooling without tap water.

Consisting of:
Cooler with tank, Pt-100, digital display, pump and liquid level indication.

Supplied with: 1 insulated hose-set (Ø 8 mm, 2x 2m)

Technical Data:
Working range: -20 to +40 °C (+5 to +32 °C at ambient temp.)
Display / Resolution: digital / 0.1 °C
Cooling capacity: 300 W at +15 °C
Pump-Pressure capacity: 10 l/min, 200 mbar
Pump-Suction capacity: 17 l/min, 180 mbar
Volume: 1.4 l
Sockets for: hose (Ø 8 /12 mm)
Dimensions / Weight: 23 x 36 x 38 cm (WxDxH), 23 kg
Power supply: 230 V, 50/60 Hz, 2.8 A, EU-plug

 

12-0559

 

Calibration Set - TAG

Consisting of:
1 calibration cover,
1 thermometer ASTM 9C/IP 15C,
1 thermometer IP 57C

 

50-9114

 

Reference Liquid - Flash-Point - TAG

ASTM D 56
Certified Value: +55 °C
Content: 255 ml
Note: Requires special shipment as hazardous goods.

 

12-1760

 

Holding Device for Multi-Detector (PMA & ABA/TAG)

suitable for:
- calibration services: to calibrate the Pt-100
- customers: to check the functionallity of Pt-100 & thermocouple
   requires: laboratory stand (e.g. 50-5001, 50-5013, 50-5031) and
                  multi-meter (Ohm & mV)

 

12-1509

 

Stand to hold 12 multi-detectors

 

12-1763

 

Storage Box

Storage box

for spare parts and tools

 

11-0599

 

USB/RS232-Converter (verified for petrotest®-units)

USB/RS232-Converter

with 2 m cable connecting 1 serial port with the USB-port of a PC or Hub

 

25-0282

 

Impact Printer (mono)

Serial Printer

for single sheets & continuous paper
to record data like test results, duration of test, etc. (instead of a PC)

Supplied with: 2 data cables (9-pin 25-0304, USB 25-0918), 1 ink ribbon (black)

Technical Data:
Line spacing: 80 characters per line (10 cpi)
Page size : 257 x 364 mm (sheet), 254 x 558.8 mm (roll)
Ports: serial (9-pin), USB (1.1)
Dimensions: 37 x 28 x 16 cm (WxDxH)
Weight: 5 kg
Power supply: 220/240 V, 50/60 Hz

 



12-1514

 

Rapidflash Simulation Set

Rapidflash Simulation Set

Consisting of:
1 rapidflash cup, 1 rapidflash cover, 1 stopper, 1 syringe and
1 multi-detector

Note! Flash-point results of rapidflash simulation may deviate from standard results.

 

12-1515

 

Rapidflash Cup

 

12-1516

 

Rapidflash Cover, with shuttler assembly

 

12-1518

 

Syringe for sample introduction, 10 ml

 

12-0577

 

Multi-Detector - pAB/pTA

Multi-Detector - pAB/pTA

for milli-tests or rapidflash-tests,
with flash-point detector and temperature probe

 

12-0560

 

Milli Cup - pTA

for sample qunatity between 2 to 15 ml, ideal 7 ml

 

12-0549

 

Standard Cover - TAG, with shutter assembly

 

12-0577

 

Multi-Detector - pAB/pTA

Multi-Detector - pAB/pTA

for milli-tests or rapidflash-tests,
with flash-point detector and temperature probe

 

12-0553

 

Standard Test Insert - TAG (incl. in TAG 4)

Consisting of:
1 cup and 1 cover

 

12-2550

 

Standard Multi-Detector - TAG, with DKD-certificate

Multi-Detector - TAG

Like 12-0550 but:
with officially certified values at -20 / 0 / +25 / +35 / +50 / +70 / +105 °C

 

12-1550

 

Multi-Detector - TAG-NIRO

Multi-Detector - TAG-NIRO

with flash-point detector (thermocouple) and
temperature probe made of stainless steel
(alternative to standardized type)

 
Spare Parts   

12-0548

 

Standard Cup - TAG, 50 ml

 

12-0549

 

Standard Cover - TAG, with shutter assembly

 

12-0550

 

Standard Multi-Detector - TAG

Multi-Detector - TAG

with flash-point detector (thermocouple) and
temperature probe made of glass

 

12-0778

 

Electric Igniter

Electric Igniter

with connector cable and plugs

 

12-0509

 

Gas Igniter with 25 cm hose

 

12-0514

 

Safety Detector

to control gas igniter and external inflammation

 

12-0600

 

Tray for cup and multi-detector

Note! Available as an option for all units built before 05/2004.

 

12-5790

 

Tong for test cups without handle

safe handling of hot test inserts

 

12-0791

 

Stopper, brass (Ø 18 mm)

to close the thermometer or multi-detector opening of the cover before use

 
Order Guideline   

Minimum equipment:

1x 12-0540 or 12-0542, 1x Cooler, 1x 25-0228

Spares (approx. 1 year):

2x 12-0778, 1x 12-0550

Additional requirements: