Manufacturer of Petroleum Test Equipment since 1873

Product   

 Stiffness - Bending Beam Rheometer - BBR (automatic)


Main Unit   

10-0700

 

BBR - Automatic Bending Beam Rheometer

ASTM D 6648 - AASHTO T313
Superpave®: SHRP 1002, SHRP B-002

Consisting of:
Integrated programmable controller for controls and recording measured data.
Linear-electromagnetic loading unit and incremental transducer.
Compact tempering unit with heater and compressor cooling and powerful pressure/suction pump. Separate test bath with constant level maintenance. Freely selectable test temperatures.
Own layout of test records.
Note: Requires molds, sample pre-tempering unit and PC (no Laptop).

Power supply: 230/240 V, 50/60 Hz

 

10-0701

 

BBR - Automatic Bending Beam Rheometer

Like 10-0700 but:
Power supply: 115 V, 60 Hz

 






10-0702

 

BBR - Automatic Bending Beam Rheometer

Like 10-0700 but:
EN 14 771 - (NF T66-062)
Power supply: 230/240 V, 50/60 Hz

 

10-0703

 

BBR - Automatic Bending Beam Rheometer

Like 10-0700 but:
EN 14 771 - (NF T66-062)
Power supply: 115 V, 60 Hz

 


10-0706

 

Beam Casting Molds, aluminum (acc. AASHTO, ASTM, EN), pack of 5

 

10-0709

 

Beam Casting Mold, silicone, triple

 


Options & Accessories   

10-0707

 

Calibration Kit - BBR Force (with works certificate)

 

10-0716

 

Calibration Kit - BBR Force (with DKD certificate)

 


10-0708

 

Calibration Kit - BBR Temperature (with works certificate)

 

10-0717

 

Calibration Kit - BBR Temperature (with DKD certificate)

 


25-0240

 

Circulator (-28/+200)

Circulator F25-MA

For heating & cooling of instruments without circulation pump
and / or for tempering applications directly in the bath.

Consisting of:
Cooler with stainless steel bath.Thermostat with digital display, splash-proof keypad, integrated heater, pump, RS232-interface, over/under-temperature & low-level protection, adjustable pump-pressure, cooling control.

Supplied with: 1 bath cover, 1 drain tap

Note: Insulated hose-set is recommended.

Technical Data:
Working range: -28 to +200 °C (at +5 to +40 °C ambient temp.)
Display / Resolution: LED / 0.01 or 0.1 °C
Heater capacity: 2000 W
Cooling capacity: 260 W at +20 °C
Pump-Pressure capacity: 11-16 l/min, , 0.23-0.45 bar (3.3-6.5 psi)
Bath opening: 12 x 14 x 14 cm (WxDxH)
Safety class / Bath fluid: 3 / FL (Flammable Liquids possible)
Volume: 4.5 l
Sockets for: hose (Ø 8 / 10 mm), solenoid valve
Dimensions / Weight: 23 x 42 x 61 cm (WxDxH), 31 kg
Power supply: 230 V, 50/60 Hz, 12 A, EU-plug

 

25-0241

 

Circulator (-28/+200)

Like 25-0240 but:
Heater capacity: 1000 W
Power supply: 115 V, 60 Hz, US-plug

 
Order Guideline   

Minimum equipment:

1x 10-0700 + 10-0706

Spares (approx. 1 year):

Additional requirements:

Coolingbath for sample pre-tempering (ASTM D 6648), Computer