Manufacturer of Petroleum Test Equipment since 1873

Product   

 Coulometer - Karl-Fischer Method - CKF 1 (automatic)


Main Unit   

16-1880

 

Coulometer acc. Karl Fischer - CKF 1

ASTM D 1533 - ASTM D 4928 - ASTM D 6304 - IP 386 - IP 438 -
ISO 10 101-3 - ISO 10 337 - ISO 12 937 - IEC 60 814

Easy to use, simple to programme so that only a single button needs to be pressed for a titration, everything else is automatic. Specially designed for outdoor use and portability. Built with 40 character backlid LCD , 15 key touchpad, 42 character high speed thermal printer, calendar & clock for analysis time & date print out, battery low indicator, data storage possibility on removable flash drive (memory stick)

Consisting of:
1 Low Drift Cell Assembly (titration vessel with 2 injection ports,
   a generator & detector electrode port and a drying tube port)
1 Generator Electrode (combined electrolysis cell)
1 Detector Electrode (dual platinum, AC polarization current / resistance measurement)
1 Drying Tube (contains molecular sieve to stop atmospheric moisture from contaminating cell and
   electrodes, cap and 100 ml desiccant)
1 Glass Syringe (1 ml) with Luer Needle, 10 Injection Septa, 1 Stirrer Bar, 2 Thermal Paper Rolls

Supplied with:
Results Manager Software Package, battery pack, power adapter, car adapter and mains lead.

Power supply: 90-264 V, 47-63 Hz, 12 V DC+ battery

 
Options & Accessories   

16-1859

 

Water Standard, 10 ampoules each 8 ml, 0.01 %

 

16-1858

 

Water Standard, 10 ampoules each 8 ml, 0.10 %

 

16-1864

 

Reagent Hydranal-Coulomat A, 500 ml (anode reagent)

 

16-1884

 

Cou-Lo Reagent Kit (Formula A+C) for oil analysis

Consisting of:
8 x anode reagent (Formula A), 100 ml, single-shot screw top bottles
8 x cathode reagent (Formula C), 5 ml, easy-snap ampoules

 

16-1881

 

Carry case with internal storage compartment

 

16-1891

 

Moisture Evaporator

ASTM D 6304 - ISO 10336 - IP 356 - JIS K2275

In combination with the Coulometer acc. Karl Fischer (CKF 1)
for water content determination of heavy oils, greases and lube oils
which contain additives that interfere with the Karl Fischer reagents.

• Digital temperature control
• Rotameter carrier gas flow control
• Built-in carrier gas drying system
• Operating temperature ambient up to 200°C
• Heated transfer tube
• Overheating protection
• Automatic cell evacuation system

Temperature Range: ambient to +200 °C
Heating method: cartridge base heater
Ambient conditions: 5 - 35°C, less than 85% RH
Dimensions (WxDxH): 320 x 210 x 330 mm, Weight approx. 6 kg

Power supply: 200-240, 50/60Hz, 400 W

 
Spare Parts   

16-1885

 

Detector Elektrode with connector

 

16-1886

 

Generator Electrode (with frit)

 

16-1887

 

Paper for thermal printer, 1 roll

 

16-1888

 

Titration Vessel, twin port

 

16-1889

 

Injection Septa (pack of 10)

 

16-1892

 

Syringe with Luer lock needle, 1 ml, glass

 
Order Guideline   

Minimum equipment:

1x 16-1880

Spares (approx. 1 year):

Reagent & Water standards

Additional requirements: