 Flash-Point with Closed Cup - Pensky-Martens Method -
PMA 4 with Sample Changer
(automatic)


Main Unit   

12-2770

 

PMA 4 S - Automatic Flash-Point Tester

PMA 4 Sampler

Pensky-Martens Method with Sample Changer

Pensky-Martens Method:
ASTM D 93-A&B - JIS K2265 - FTM 791-1102 -
FTM 141-4293 - AASHTO T73-A&B - AASHTO T172-A&B -
IP 34-A&B (BS 2839) - ISO 2719-A&B (DIN 51 758, NF M07-019) - (EN 22719)

Biodiesel Method: ASTM D 6751

Limit Test (eatable oils &fats): ISO 15 267 - BS 684-1.17

Consisting of:
PMA 4 in a high-grade stainless steel housing with two-color powder coating, touch-key panel and large LC-display, swivel-mounted multi-function-head - ONE-TWIST, two RS232-interfaces for data printer and computer connection, different test-programs, data-transfer and software upgrading through bi-directional interface, automatic barometric pressure correction, automatic overheat protection, power controlled/monitored electric igniter, gas igniter with auto-relighting and safety shut-off, re-cooling fan

Sample Changer with 12-place carrousel, transfer arm with housing and positioning devices.

PC-Software "PMANet” (Windows® compatible):
for easy handling, storing of data, as well as program transfer from PC to PMA 4. Easy to read tableau. Permanent indication of test status. Results can be stored in the memory and transferred into Excel etc. Numerous programs can easily be set (e.g. Bitumen-program), copied from the memory and modified. Due to the most comfortable ability of this software to display and modify actual and future test sequences, it is most recommendable for samples of permanently changing characteristics. Graphical display of sample & block temperature, as well as temperature gradient.

When using the auto-sampler the software is also able to use the result of the previous test as the estimated flashpoint for the next test automatically. Important for unknown samples.
Including the module "Quick Run", especially useful in connection with the sample changer. The re-cooling time is optimized in relation to the next consecutive sample. Rationalization of up to 50% becomes possible. Full compliance with standards is ensured.

Supplied with:
1 gas igniter
1 electric igniter
1 tong for cup
1 stirrer coupling
1 PC-software "PMANet" (incl. "QuickRun")

To be ordered separately:
Test inserts (cups, covers) & multi-detectors (e.g. 12-0777 & 12-0787)

Temperature Range: +40 to +360 °C (+104 to +680 °F)

Power supply: 115/230 V, 50/60 Hz, EU-plug

 

12-2771

 

PMA 4 S - Automatic Flash-Point Tester

Pensky-Martens Method with Sample Changer

Like 12-2770 but:
Power supply: 115/230 V, 50/60 Hz, US-plug

 



12-2772

 

PMA 4 FS - Automatic Flash-Point Tester

PMA 4 with Fire-Extinguishing Device and Sample Changer

Pensky-Martens Method with Fire-Extinguishing
Device & Sample Changer

Like 12-2770 but:
with automatic fire-suppression system for connection to external Nitrogen- or Carbon Dioxide supply.

Power supply: 115/230 V, 50/60 Hz, EU-plug

 

12-2773

 

PMA 4 FS - Automatic Flash-Point Tester

Pensky-Martens Method with Fire-Extinguishing
Device & Sample Changer

Like 12-2772 but:
Power supply: 115/230 V, 50/60 Hz, US-plug

 



12-2776

 

PMA 4 SC - Automatic Flash-Point Tester

PMA 4 with Chilled Sampler Set

Pensky-Martens Method with Chilled Sampler Set

Like 12-2770 but:
with insulating cover and coolant circulator with tubing.

The carrousel is made out of a two-layer metal block with an internal heat exchanger coil to stabilize the temperature to a level deviating from the ambient temperature. An acrylic-glass cover is designed to reduce the loss of cooling energy.

A mechanically refrigerated coolant circulator is used as a source of cooling energy to keep the temperature in the samples at approx. +4°C (ambient not exceeding +24°C). Connecting tubes are insulated.

Temperature Range: approx. +4°C to +360°C

Power supply: 115/230 V, 50/60 Hz, EU-plug

 

12-2777

 

PMA 4 SC - Automatic Flash-Point Tester

Pensky-Martens Method with Chilled Sampler Set

Like 12-2776 but:
Power supply: 115/230 V, 50/60 Hz, US-plug

 



12-2778

 

PMA 4 FSC - Automatic Flash-Point Tester

Pensky-Martens Method with Fire-Extinguishing Device & Chilled Sampler Set

Like 12-2770 but:
with automatic fire-suppression system, insulating cover and coolant circulator with tubing.

Power supply: 115/230 V, 50/60 Hz, EU-plug

 

12-2779

 

PMA 4 FSC - Automatic Flash-Point Tester

Pensky-Martens Method with Fire-Extinguishing Device & Chilled Sampler Set

Like 12-2778 but:
Power supply: 115/230 V, 50/60 Hz, US-plug

 




Options & Accessories   

12-0777

 

Standard Test Insert "PM"

Standard Test Insert - PM

Consisting of:
1 cup and 1 cover
(standard dimensions, made of brass)

 

12-0785

 

Standard Cup "PM"

approx. 75 ml (with filling mark), made of brass

 

12-0786

 

Standard Cover "PM"

for standard cup with shutter assembly, made of brass

 

12-0787

 

Standard Multi-Detector "PM"

with flash-point detector (thermocouple) and
temperature probe (made of glass)

 

12-1790

 

Test Insert "PM-NIRO"

Test Insert - Stainless Steel

Consisting of:
1 cup and 1 cover
(standard dimensions, made of stainless steel)

 

12-1791

 

Cup "PM-NIRO"

approx. 75 ml ( with filling mark), made of stainless steel

 

12-1792

 

Cover "PM-NIRO"

for test cup with shutter assembly, made of stainless steel

 

12-0784

 

Multi-Detector "PM-NIRO"

with flash-point detector and temperature probe
(made of stainless steel)

 

12-1777

 

Milli Test Insert "pPM"

Milli Test Insert

Consisting of:
1 cup and 1 cover
for sample quantity between 2...15 ml, ideal 7 ml,
made of brass

 

12-1785

 

Milli Cup "pPM"

approx. 15 ml, made of brass

 

12-1786

 

Milli Cover "pPM"

for test cup with shutter assembly, made of brass

 

12-1787

 

Milli Multi-Detector "pPM"

with flash-point detector (thermocouple) and
temperature probe (made of stainless steel)

 

12-0782

 

Calibration Set - PMA/PM

Calibration Set - PMA/PM

Consisting of:
1 calibration cover,
1 thermometer ASTM 9C/IP 15C,
1 thermometer ASTM 10C/IP 16C

 

12-1762

 

Calibration-Adapter for Pt-100 in multi-detector

 

12-0793

 

Handle for permanent fixing at the cup

 

12-1508

 

Draft Deflector (recommended for gas ignition tests)

 

12-1509

 

Stand to hold 12 multi-detectors

 

12-1763

 

Storage Box for spare parts and tools

 

50-9110

 

Reference Liquid, Flash-Point - ASTM D 93

(Pensky-Martens)

Flash Point: approx. +65°C
Content: 255 ml
Note: Requires special shipment as hazardous goods.

 

50-9112

 

Reference Liquid, Flash-Point - ASTM D 93

(Pensky-Martens)

Flash Point: +213°C
Content: 250 ml

 

50-9113

 

Reference Liquid, Flash-Point - ASTM D 93

Reference Liquid, Flash-Point - ASTM D 93

(Pensky-Martens)

Flash Point: approx. +57.0 °C
Content: 250 ml
Note: Requires special shipment as hazardous goods.

 

50-9024

 

MTVM - Reference Liquid (Gas Oil)

with certificate (ISO 9001), 500 ml

 

25-0804

 

Computer with Monitor

(detailed specifications upon request)
Power supply: 230 V, 50 Hz

 

11-0599

 

USB/RS232-Converter (verified for petrotest®-units)

USB/RS232-Converter

with 2 m cable connecting 1 serial port with the USB-port of a PC or Hub

 

25-0282

 

Impact Printer (mono)

Serial Printer

for single sheets & continuous paper
to record data like test results, duration of test, etc. (instead of a PC)

Supplied with: 2 data cables (9-pin 25-0304, USB 25-0918), 1 ink ribbon (black)

Technical Data:
Line spacing: 80 characters per line (10 cpi)
Page size : 257 x 364 mm (sheet), 254 x 558.8 mm (roll)
Ports: serial (9-pin), USB (1.1)
Dimensions: 37 x 28 x 16 cm (WxDxH)
Weight: 5 kg
Power supply: 220/240 V, 50/60 Hz

 

25-0283

 

Impact Printer

Like 25-0282 but:
Power supply: 110/130 V, 50/60 Hz

 
Spare Parts   

12-0600

 

Tray for cup and multi-detector

Note! Available as an option for all units built before 05/2004.

 

12-0790

 

Tong for safe handling of hot handleless test cups

 

12-0778

 

Electric Igniter with connector cable and plugs

 

12-0779

 

Gas Igniter with 20 cm hose

 

12-0781

 

Gas Supply Tubing, 1 meter

 

12-0788

 

Safety Detector

to control gas igniter and external inflammation

 

12-0780

 

Stirrer Couplings for units built until 12/2001, pack of 10

 

12-1507

 

Stirrer Couplings , pack of 10

 

12-0791

 

Stopper, brass (Ø 18 mm)

to close the thermometer or multi-detector opening of the cover before use

 
Order Guideline   

Minimum equipment:

1x PMA 4 Sampler (see above)

Spares (approx. 1 year):

1x 12-0787, 2x 12-0778, 1x stirrer couplings

Additional requirements:

Gas & electrical supply