Versatility
The user of the PMA 4 is not bound to the standardized test methods
only but can adapt the instrument to individual requirements.
Reliable and Precise
The operator has the choice to either apply a gas flame or an
electrical igniter.
The gas flame is controlled and if blown off automatically
re-lit.
The PMA 4 measures the barometric pressure during the flash and
makes an automatic correction.
The temperature indication can be checked using a special probe
verification program, in conjunction with a special test lid and a
certified thermometer.
Time Saving and Economical to Operate
For samples with a high flash-point the RAPID-heating program heats
at an accelerated rate of 8.5 K/min, until 30 K below the expected
flash-point, when the heating rate is reduced to the standardized
rate of 5 to 6 K/min.
The SEARCH program enables a quick determination of fully unknown
samples. The PMA 4 heats the sample at 8.5 K/min and the igniter is
automatically applied every 5 K.
Operational Safety
The PMA 4 is equipped with multiple sensors which monitor the
proper functioning of this instrument.
One sensor continually checks the performance of the electric
igniter. Outside of control limits a warning is displayed.
If gases burn outside the sample cup, it will be detected and
signaled to prevent an accident or damage.
|
PC-Software "FPPnet" (Windows®):
A control & analysis program for easy handling, data storage and program transfer. Providing online display of sample & heater block temperature, gradient (also in an XY-diagram) and test status. Easy to read tableau indicating: sample no., sample name, °C/°F, expected flash point, program, status, found flash point, corrected flash point, corrected rounded flash point.
Test results are stored together with all program and device parameters in one file. The simultaneous connection of different petrotest® flash point devices is possible. To simplify the device management they can be named individually.
With the sample changer the software is able to use the result of the previous test as the estimated flashpoint for the next test automatically (important for unknown samples).
pPM - Cup
This is a special test insert with a volume of approx. 15 ml
(Milli-Test-Insert).
Although this cup does not comply with the official standards,
experiments have shown that in many cases and even with a sample
volume of only 2 ml, good reproducibility and test results
can be achieved which agree well with those measuring strictly
according to the standards.
Fire Extinguisher
The PMA 4 is available with a fire extinguishing option, too.
It requires external Nitrogen- or Carbon Dioxide supply.
Automatic Sample Changer
As an exceptionally time and cost saving alternative,
the PMA 4 is available with an automatic sample changing
device.
This carrousel can carrying a maximum of 12 test cups.
|