Manufacturer of Petroleum Test Equipment since 1873

Product   

 Evaporation Loss of Lubricants (manual)

Standard(s): 

ASTM D 972, ASTM D 2878, FTM 791-0351, IP 183, JIS K2220


 

Product group(s): Oil

User group(s): Lube Oil, Lubricating Grease, Oil

Scope:

These methods cover the determination of evaporation loss of lubricating greases and oils a sample cup in an evaporation cell is placed in a bath and maintained at temperatures in the range from 210 to 400 °F (99 to 200 °C). Heated air is passed over its surface for 22 hours.


The evaporation loss is calculated from the loss in weight of the sample.